<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-04 18-18-56
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 70 dBuV Classic
Pilot RDS Phase Difference
7.0 kHz 3.5 kHz 82 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 64 kHz 18990 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,1 dBr 2,49 dBr 3,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Salonorchest "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 64 kHz MIN: 10 kHz % above 76 kHz: 0,0000 Acquired: 2025/01/04 18.17.52 Total samples: 18990 Equivalent time: 0:15:49 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 3,3 dBr MIN: 1,1 dBr AVE: 2,49 dBr % above 12,2 dBr: 0,0 Last value: 2,1 dBr (2025/01/04 18.17.52) 18.04 18.06 18.08 18.10 18.12 18.14 18.16 -1 0 1 2 3 4 Pm [dBr]